Manual path switching, Manual path switching -19 – HP Hitachi Dynamic Link Manager Software User Manual

Page 39

Advertising
background image

HDLM automatically places the recovered path online, the path that is

currently being used will continue to be used (as opposed to switching over to

the path that was just recovered).

When intermittent errors

#

occur on paths and you are using the automatic

failback function, the path status might frequently alternate between the

online and offline statuses. In such a case, because the performance of I/Os

will most likely decrease, if there are particular paths in which intermittent

errors might be occurring, we recommend that you set up intermittent error

monitoring so you can detect these paths, and then remove them from those

subject to automatic failbacks.

You can specify the automatic failback or intermittent error monitoring

function from the Options window of the HDLM GUI or by using the dlnkmgr

command's set operation. For details on operations from the Options

window, see the HDLM GUI Help. For details on the set operation, see

set

(Sets Up the Operating Environment) on page 6-15

.

#

An intermittent error means an error that occurs irregularly because of

some reason such as a loose cable connection.

Manual Path Switching

You can switch the status of a path by manually placing the path online or

offline. Manually switching a path is useful, for example, when system

maintenance needs to be done.

You can manually place a path online or offline by doing the following:

Use the HDLM GUI Path Management window.

Execute the dlnkmgr command's online or offline operation.
For details on the online operation, see

online (Places Paths Online) on

page 6-10

. For details on the offline operation, see

offline (Places

Paths Offline) on page 6-6

.

However, if there is only one online path for a particular LU, that path cannot

be manually switched offline. Also, a path with an error that has not been

recovered from yet cannot be switched online.

HDLM uses the same algorithms to select the path that will be used next,

regardless of whether automatic or manual path switching is used.

When using the Thunder 9500V series, or Hitachi AMS/WMS series, HDLM will

select the next path to be used first from among the online owner paths, and

then from the online non-owner paths. When the Lightning 9900 series,

Lightning 9900V series, Hitachi USP, Universal Storage Platform V/VM, Virtual

Storage Platform, Hitachi AMS2000 series, or Hitachi SMS is being used, all

the paths that access the same LU as the path that is currently being used

are candidates for the switching destination path.

By changing the path status to online in the Path Management window, or by

executing the online operation, an offline path can be placed online. For

details on the online operation, see

online (Places Paths Online) on page

HDLM Functions

2-19

Hitachi Dynamic Link Manager User Guide (for Windows(R))