Reports – HP Integrity rx2800 i2 Server User Manual
Page 85
Scripted deployment 85
UID=Userid
PWD=password
[END]
Example 4
SILENT = YES
IGNOREERRORS = ServerNotFound,BadPassword, FailedDepedencies
SKIPTARGET = NO
SOURCEPATH = C:\ fwcd\firmware-8.70-0\hp\swpackages
FORCEALL = YES
REBOOTALLOWED = YES
REBOOTDELAY = 30
REBOOTMESSAGE = “Install complete, server will reboot in 30 seconds”
[TARGETS]
HOST=16.83.62.141
UID=Userid
PWD=password
[END]
[TARGETS]
HOST=16.83.61.48
UID=Userid
PWD=password
[END]
[TARGETS]
HOST=16.83.62.196
UID=Userid
PWD=password
[END]
[TARGETS]
HOST=16.83.61.24
UID=Userid
PWD=password
[END]
Reports
HP SUM can generate three types of reports about the specified system or repository. You can only generate
the reports using the command-line arguments provided. If no additional arguments are specified on the
command line, the local host and default repository locations (the directory where HP SUM was initiated) are
used. You can specify a target with appropriate credentials and a repository using other command-line
parameters if you want to generate reports for other systems and repositories. For specific commands, see
"Command-line interface (on page
)."
Report type
Description
Report file information*
/report
This argument generates a report listing,
a target summary, and how the
components in the repository affect the
target (for example, whether each
component applies to the target or not).
The report files generated are:
•
hpsum_Report_<date>.html
•
hpsum_Report_<date>.xml