Troubleshooting 66

Troubleshooting

Troubleshooting table

Issue

Troubleshooting

Data loss in Toolkit

Improper use of the Toolkit utilities and modification of the CONREP data files can

result in loss of critical data. Because of the potential data-loss risk, only
experienced individuals should use the Toolkit utilities. Before using the Toolkit, all

necessary precautions must be taken to ensure that mission-critical systems remain
online if a failure occurs.

Configuring options

using Toolkit utilities

Not all options can be configured using Toolkit utilities. Some options must be

configured manually or with other configuration utilities, which are available
online, before they can be used with the Toolkit. For more information on

configuration, see the option documentation.

Input files for

HPONCFG

Because the -w argument does not capture certain types of information, such as the

administrator password, data files created with HPONCFG using the -w argument
cannot then be used as input files for HPONCFG, unless they are modified first.

Sample script files

The script files and script segments in this guide are provided only as examples.
You must modify the scripts for your environment. When creating or modifying your

own scripts, the pause command is a valuable tool to help you determine that each
step of the script is functioning as desired.

HP ProLiant drivers

HP ProLiant drivers must be added during Windows® PE customization to ensure

the Toolkit utilities function properly. See the readme.txt file provided.

WMI support

HP software requires that WMI support be enabled to function in Windows® PE
properly.

Non-functioning IFHW IFHW is case-sensitive. Incorrect case, misspellings, and incorrect spacing cause

the query to fail.

CONREP version
compatibility

The file format for the DOS version of CONREP and the current version of CONREP
are not compatible.

HPACUSCRIPTING

support

HPACUSCRIPTING supports only HP Smart Array controllers. Review the

HPACUSCRIPTING documentation for the latest information.

Booting from a USB

drive key

Booting from a USB drive key is supported only on certain ProLiant servers. For

more information, see the HP Insight Foundation suite for ProLiant website
(

http://www.hp.com/go/foundation

).

Customizing the

DEPLOYSERVER.CMD
script

The IFHW and HWQUERY utilities can be used to customize the

DEPLOYSERVER.CMD script for your environment. For more information about
these utilities, see the Toolkit utilities (on page

26

) section.

SETBOOTORDER

changes

Any changes you make to the SETBOOTORDER will take effect at the next reboot.