For a new component record, the following default values are displayed in the Alarms table:

Selected XP or P9000 disk array name under Array

Selected component under Resource

Selected metric category under Metric Category

Selected metric under Metric

999999 under Threshold

The destination email and SNMP addresses configured on the Email Settings screen (PA and DB
Settings > Email Settings. If not configured, the Email Destination and SNMP Destination fields are
shown blank.

IMPORTANT:

P9000 Performance Advisor does not support the THP Pool RG Utilization and LDEV RG Utilization
metrics. Thus, you cannot create an alarm using these metrics. Alarms that are created earlier using
these metrics will be removed when you upgrade from any previous version to P9000 Performance
Advisor v5.4.

Related Topics

Setting threshold level

” on page 142

Configuring alarm notifications

” on page 143

Establishing scripts for alarms

” on page 145

Enabling or disabling alarms

” on page 146

Applying a template

” on page 147

Deleting records in the Alarms table

” on page 148

Configuring notification and monitoring settings

After you select components and metrics, and click Add alarm(s), records for the components are
added to the Alarms table. You must configure the following settings for the components, so that
P9000 Performance Advisor can monitor the selected components:

Setting threshold levels. For more information, see

Setting threshold level

” on page 142

Specifying destinations. For more information, see

Configuring alarm notifications

” on page 143

Specifying script destinations. For more information, see

Establishing scripts for alarms

” on page 145

Enabling or disabling alarms (see

Enabling or disabling alarms

” on page 146

Using the configured settings of a previous record as a template. For more information, see

Ap-

plying a template

” on page 147

Configuring alarms and managing events

140

Advertising
This manual is related to the following products: