Installation overview 10

6.

Configure, and then test the WinRM listener on the server.

7.

Perform additional configuration, if required, like firewall configuration on the server.

8.

Install the BACS management application.

Microsoft Windows client
Use the following items to install BACS on a Microsoft Windows client. For the complete installation
instructions, see "Installing BACS components on Microsoft and Linux operating systems (on page

12

)."

To install BACS on a Microsoft Windows client:

1.

If you plan to use HTTP with WS-MAN, perform HTTP configuration on a client.

2.

If you plan to use HTTPS with WS-MAN, perform HTTPS configuration on a client.

3.

Configure WinRM listener on a client.

4.

Install the BACS client application on client systems.

The WMI protocol is only supported on Microsoft Windows OS. CimXML is not supported on Microsoft

Windows OS.
BACS WMI on a Microsoft Windows server
Use the following items to install BACS WMI on a Microsoft Windows server. For the complete installation

instructions, see "Setting up namespace security using WMI control (on page

26

)."

To install BACS WMI on a Microsoft Windows server:

1.

Set namespace security using WMI control.

2.

Grant DCOM remote launch, and then activate permission for a user or group.

3.

Perform special configuration, if necessary.

4.

Follow the standard Microsoft Windows client installation steps to use WMI on a Microsoft Windows
client.

Installation summary for Linux operating systems

Use the following items to install BACS on a Linux server. For the complete installation instructions, see
"Installing BACS components on Microsoft and Linux operating systems (on page

12

)."

Install the following items in the following order:

1.

OpenSSL

2.

Pegasus

3.

BRCM_CMPIProvider-x.x.x.rpm

4.

BACS-x.x.x.rpm

There are two installation options available with OpenPegasus–Inbox RPM or from source. The Inbox
OpenPegasus is only available on Red Hat OS. For SLES11, the only available option is the source RPM.
WS-MAN is not supported with the Inbox RPM. To use WS-MAN, install OpenPegasus from source.
To install BACS on a Linux server:

1.

Install OpenPegasus on server from source RPM.

2.

Start CIM Server on the server.

3.

Configure OpenPegasus on server.

4.

Install Broadcom CIM provider.

Advertising