Manual path switching, Manual path switching -19 – HP XP P9500 Storage User Manual

Page 41

Advertising
background image

#1

This storage system applies when the dynamic I/O path control function is

disabled.

#2

An intermittent error means an error that occurs irregularly because of

some reason such as a loose cable connection.

Manual path switching

You can switch the status of a path by manually placing the path online or

offline. Manually switching a path is useful, for example, when system

maintenance needs to be done.

You can manually place a path online or offline by doing the following:

Execute the dlnkmgr command's online or offline operation.
For details on the online operation, see

online (Places Paths Online) on

page 6-11

. For details on the offline operation, see

offline (Places

Paths Offline) on page 6-6

.

However, if there is only one online path for a particular LU, that path cannot

be manually switched offline. Also, a path with an error that has not been

recovered from yet cannot be switched online.

HDLM uses the same algorithms to select the path that will be used next,

regardless of whether automatic or manual path switching is used.

When using the Thunder 9500V series, or Hitachi AMS/WMS series HDLM

selects the switching destination path from owner paths and then from non-

owner paths. When the Lightning 9900V series, Hitachi USP series, Universal

Storage Platform V/VM series, Virtual Storage Platform series, Hitachi
AMS2000 series

#

, Hitachi SMS series

#

, HUS100 series

#

, or HUS VM is being

used, all paths that access the same LU are candidates for the switching

destination path. All other paths that run through the same physical path are

switched.

Executing the online operation places the offline path online. For details on

the online operation, see

online (Places Paths Online) on page 6-11

. After

the path status is changed to online (by executing the online operation),

HDLM selects the path to use in the same way as for automatic path

switching. When using the Thunder 9500V series, or Hitachi AMS/WMS series

HDLM selects the path to use from online owner paths, and then from online

non-owner paths. When the Lightning 9900V series, Hitachi USP series,

Universal Storage Platform V/VM series, Virtual Storage Platform series,
Hitachi AMS2000 series

#

, Hitachi SMS series

#

, HUS100 series

#

, or HUS VM is

being used, since all the paths are owner paths, the path to use is not

switched even if you change the path status to online by using the online

operation.

#

HDLM Functions

2-19

Hitachi Dynamic Link Manager User Guide for AIX

®

Advertising
This manual is related to the following products: