HP XP7 Storage User Manual

Page 62

Advertising
background image

2.

Click Edit SCP Time.

3.

In the Edit SCP Time window, select the CU for which you want to change the
state-change-pending time and click Change SCP Time.

4.

In the Change SCP Time window, enter the state-change-pending time you want to set and
click OK.

5.

Click Finish.

6.

In the Confirm window, enter a Task Name and click Apply.

The Task window appears after the registration if you marked Go to tasks window for status.

Related topic

Page 118

Viewing relationship states of Compatible FlashCopy

To view the states of Compatible FlashCopy relationships, use any of the following PPRC TSO
commands:

FCQUERY

ICKDSF

ANTRQST Macro

z/VM CP

Using TSO FCQuery command to view relationship states of Compatible FlashCopy

The following table shows the parameter you can use with the FCQUERY command to view
relationship states:

Table 34 Parameters for the FCQUERY command

Description

Value

Parameter

Specify the number (device address) of the Compatible FlashCopy volume on
which you want to see its status.

Device number

DEVN

You use the Remote FlashCopy function to establish a relationship.

YES

REMOTE

You do not use the Remote FlashCopy function.

NO

NO is the default setting.

Specifies the SSID of the CU on which you establish the FlashCopy relationship.

SSID

QRYSSID

Use this parameter when REMOTE is YES.

Specifies the device number, the CU number, or the LDEV number of the S-VOL
when you use the Remote FlashCopy function.

Device number

CU number

QRYDVC

Use this parameter when REMOTE is YES.

LDEV number

Displays detailed relationship information.

ALL

SHOWRELS

Does not display detailed information about relationships. If the SHOWRELS
parameter is not specified, NO is set by default.

NO

Displays the same information as for ALL. However, detailed information is shown
only for the specified number of relationships.

Integer between 1 and
9999

Specifies the CCHH number of the starting address. Use this parameter when
the relationship number is specified in the SHOWRELS parameter.

CCHH number

STARTADDR