Diagnostic application, Operation – HP StoreEver MSL6480 Tape Library User Manual

Page 54

Advertising
background image

Table 3 Event Log Entries (continued)

Message

Severity

Event

Path failure detected on SCSI Port %s
Bus %3 Target Id %4 Logical Unit %5

Error

Path failure detected

Failover session established on SCSI
Port %2 SCSI Bus %3 Target Id %4
Logical Unit %5

Informational

Failover session established

Failover session establishment error on
SCSI Port %2 SCSI Bus %3 Target Id
%4 Logical Unit %5. Reason code %6.

Error

Failover session establishment error

The reason code for a failover session establishment error is a Windows system error number.
Because there is no particular action that the user can take that depends upon the error code, the
values are not described here. The reason code should be included with the rest of the message
in any report sent to technical support.

For simplified viewing, the Windows system Event Log may be filtered using the 'Actions' panel
and selecting just events from HPtapeFailover_filt and HPtapeFailover_mpio. Including
events from UserPnp may also provide additional helpful information.

Diagnostic application

The Advanced Failover Diagnostic application communicates with the drivers to obtain the state
of failover sessions. The diagnostic application is installed with the driver and can be found in the
driver installation directory, C:\Program Files\Hewlett-Packard\Advanced Failover
Drivers\Utils

.

The application consists of two files, HPAdvFoDgn.exe and HPtapeFailover_mpio.dll.

Operation

The diagnostic application is started by double-clicking its icon. It displays a windows like the
window shown in

Figure 19 (page 55)

. The window contains four panes:

54

Troubleshooting failover operation