Command error messages – HP XP RAID Manager Software User Manual

Page 194

Advertising
background image

Table 40 System log messages (continued)

Recommended action

Cause

Condition

Message ID

Refer to the HORCM startup log to identify
the cause of the error.

A system I/O error occurred or
an error exists in the HORCM

HORC/HOMRCF and the
RAID Manager software
communication fails.

HORCM_101

configuration file
($HORCM_CONF).

Call HP Technical Support.

The pair status was suspended
due to code XXXX.

The volume is suspended.

HORCM_102

Please confirm the following items, and
use raidvchkdsp -v <op> command
for verifying the validation parameters.

A validation error occurs on the
database volume, or validation
parameters for this volume are
illegal.

Detected a validation check
error on this volume (xxxx
unit#x,ldev#x) : CfEC=n,
MNEC=n, SCEC=n,
BNEC=n

HORCM_103

(1) Check if the block size (-vs <size>) is
an appropriate size.

(2) Check if the type for checking (-vt
<type>) is an appropriate type.

(3) Check if the data validations are
disabled for LVM configuration changes.

(4) Check if the data validations are not
used based on file system.

(5) Check if the redo log and data file are
separated among the volumes.

Command error messages

The following table lists and describes the command error messages and their return values and
provides recommended action for resolving the error conditions.

Table 41 Command error messages

Value

Recommended action

Condition

Error

Error code

message

255

Verify that HORCM is running by
using UNIX commands [ps - ef |
grep horcm].

This command failed to
communicate with the RAID
Manager software.

Can’t communicate
with HORC
Manager

EX_COMERR

254

Please designate the correct option
using the -h option.

An option or arguments of
an option are not sufficient.

Required Arg list

EX_REQARG

253

Please designate the correct option
using the -h option.

An option or arguments of
an option are incorrect.

Invalid argument

EX_INVARG

252

Please designate the correct option
using the -h option.

Designated an unknown
option.

Unknown option

EX_UNWOPT

251

Please verify that HORCM is running
and/or that HORCMINST is set
correctly.

Could not connect with
HORCM.

Can’t be attached to
HORC Manager

EX_ATTHOR

250

Verify that HORCM is running by
using UNIX commands [ps - ef |
grep horcm].

Failed to communicate with
HORCM, or cannot make a
log directory file.

Can’t be attached to
a Debug layer

EX_ATTDBG

249

Please designate the correct option
using the -h option.

The name specified in an
argument of an option is not
appropriate.

Invalid name of
option

EX_INVNAM

248

Call HP Technical Support.

Detected contradiction in
information that RAID
reported.

A specified option is
invalid

EX_OPTINV

194