Cascading connection and configuration files – HP XP RAID Manager Software User Manual

Page 33

Advertising
background image

Table 5 Mirror descriptors and group assignments

Cnt Ac-J
only

Business Copy
(Snapshot) only

MU#0

HORCM_DEV parameter in configuration file

MU#1-#3

MU#1-#2
(MU#3-#63)

Business Copy

Continuous
Access
Synchronous/
Cnt Ac-J

-

-

oradev1

oradev1

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

-

oradev11

oradev1

oradev1

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

Oradb1 oradev11 CL1-D 2 1 1

Oradb2 oradev21 CL1-D 2 1 2

-

oradev21

oradev11

oradev1

HORCM_DEV

oradev31

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

Oradb1 oradev11 CL1-D 2 1 0

Oradb2 oradev21 CL1-D 2 1 1

Oradb3 oradev31 CL1-D 2 1 2

-

-

oradev1

-

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1 0

-

oradev11

oradev1

-

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1 0

Oradb1 oradev11 CL1-D 2 1 1

Oradb2 oradev21 CL1-D 2 1 2

oradev21

-

oradev11

oradev1

HORCM_DEV

oradev31

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

oradev41

Oradb1 oradev11 CL1-D 2 1 0

Oradb2 oradev21 CL1-D 2 1 h1

Oradb3 oradev31 CL1-D 2 1 h2

Oradb4 oradev41 CL1-D 2 1 h3

Cascading connection and configuration files

A volume of the cascading connection describes entity in a configuration definition file on the same
instance, and classifies connection of volume through the mirror descriptor. Also, in the case of
Continuous Access Synchronous/Business Copy cascading connection, the volume entity describes
to a configuration definition file on the same instance. The following figure shows an example of
this.

RAID Manager instance components on the host server

33

Advertising
This manual is related to the following products: