Raidexmibdkuhwtable – HP XP Racks User Manual

Page 18

Advertising
background image

Table 11 Storage system component information (continued)

Attribute

MIB value

Description

Type

Name

read-only

See Note

Status of fan.

INTEGER

dkcHWFan

::=raidExMibDKCHWEntry(8)

read-only

See Note

Information of an operational
environment.

INTEGER

dkcHWEnvironment

::=raidExMibDKCHWEntry(9)

Note:

The status of each component is a single digit which shows the following:

1: Normal.

2: Acute failure detected.

3: Serious failure detected.

4: Moderate failure detected.

5: Service failure detected.

raidExMibDKUHWTable

raidExMibDKUHWTable indicates the status of the storage system components.

raidExMibDKUHWTable OBJECT TYPE
SYNTAX SEQUENCE OF RaidExMibDKUHWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Error information of the DKU."
::={ raidExMibRoot 7}

raidExMibDKUHWEntry OBJECT TYPE
SYNTAX RaidExMibDKUHWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Entry of DKU information."
INDEX { dkuRaidListIndexSerialNumber }
::={ raidExMibDKUHWTable 1}

Table 12 Disk device components information

Attribute

MIB value

Description

Type

Name

read-only

1-99,999

Storage system product number
(index).

INTEGER

dkuRaidListIndexSerialNumber

::=raidExMibDKUHWEntry(1)

read-only

See Note

Status of power supply.

INTEGER

dkuHWPS

::=raidExMibDKUHWEntry(2)

read-only

See Note

Status of fan.

INTEGER

dkuHWFan

::=raidExMibDKUHWEntry(3)

read-only

See Note

Status of environment monitor.

INTEGER

dkuHWEnvironment

::=raidExMibDKUHWEntry(4)

read-only

See Note

Status of drive.

INTEGER

dkuHWDrive

::=raidExMibDKUHWEntry(5)

Note:

The status of each component is a single digit which shows the following:

1: Normal.

18

SNMP supported MIBs

Advertising