Remove the service-end lamp housing – HP Scitex FB700 Industrial Printer User Manual

Page 67

Advertising
background image

2.

Remove the four sliver screws (A and B in the following figure) that secure the lamp housing to
the lower lamp assembly.

Figure 9-3

User end screws

B

A

A

B

3.

LIft up to remove the lamp housing from the printer.

Remove the service-end lamp housing

1.

Disconnect the auxiliary cable from the top of the service-end lamp. See

Figure 9-1 Disconnect

the user-end auxiliary cable on page 60

for location.

2.

Remove the lamp power cable from the side of the lamp housing by turning the coupling
counterclockwise. See

Figure 9-2 Remove the user-end power cable on page 60

for location.

ENWW

Replace UV lamp bulb (500–1000 hours)

61