Scripted deployment, Command-line interface, Command-line syntax – HP ProLiant Support Pack User Manual

Page 64

Advertising
background image

Scripted deployment 64

Scripted deployment

Command-line interface

The HP SUM command-line interface enables you to script custom installations.

Command-line syntax

The general command-line syntax for HP SUM is:

hpsum [/h[elp]] [/?] [/f[orce]] [/f[orce]:bundle] [/f[orce]:rom]

[/f[orce]:software] [/f[orce]:all ] [/g (/downgrade)] [/e (/rewrite)]

[/m[utual])] [/c[omponent] <component_to_install>] [/s[ilent]]

[/allow_update_to_bundle] [/allow_non_bundle_components] [/b[undle]

<bundle_to_install>] [/express_install] [/use_snmp] [/use_location

"file_share"] [/use_web]* [use_proxy]* [proxy_server]*

[/use_d[ownloaded]*] [/tpmbypass] [/ignore_tpm] [/use_wmi] [/use_latest]

[/romonly] [/softwareonly] [/continue_on_error <error>]

[/override_existing_connection] [/On_failed_dependency:<Parameter>]

[/r[eboot]] [/reboot_message "reboot message"] [/reboot_delay

timeout_in_seconds] [/reboot_always] [/dryrun] user <username> or

/username <username>] [/passwd <password>] [/current_credential]

[/target "netAddress"] [/group "group_name"] [/ [/logdir "path"]

[/v[erbose]] [/veryv[erbose]] [/report] [/inventory_report]

[/firmware_report] [/inputfile "filename"] [/deleteinputfile

"filename"][<component1_to_install> <component2_to_install> ...]

[<bundle1_to_install> <bundle2_to_install> ...]

HP SUM with Onboard Administrator requires a user ID and password to log in. The user ID must be an
Administrator equivalent ID and not an operator or user equivalent level ID.

NOTE:

All arguments and information enclosed in brackets are optional. The arguments may

be prefixed with either a '-' or '/' character. These examples show only the '/'.

On Windows® operating systems, use a slash (/) before each argument. On Linux operating systems, use

a hyphen (-) before each argument.
If the /s[ilent] argument is not included on the command line, the HP SUM GUI appears.

NOTE:

Command line syntax does not support double-byte character sets. Any messages

entered through the command line using a double-byte character set will not be displayed
correctly.

NOTE:

When using HP SUM with HP Integrity BL860c/BL870c/BL890c i2 Server bundles,

HP SUM does not have any command-line arguments to specify the Upload and Do Not

activate option. If HP SUM is started from the command line using the silent argument
(/s[ilent]), then the system being updated reboots automatically. Also, no reporting

functionality using CLI is available when using HP SUM for firmware updates on these servers.

Advertising
This manual is related to the following products: