Remote control with pushbutton (option), Remote control with switch (option), Operating modes – Karcher IVL 120-27-1 User Manual

Page 8: Operation, Parameters of the plc control, Operating modes 1 1 operation

Advertising
background image

– 2

Part no. 4.812-068.0

1 Pushbutton incl. indicator lamp of the

remote control

1 Switch of the remote control

Note: Various operating modes can be set
via the parameters of the PLC control.
1 Pushbutton operation of the remote

control: pushing 1x = vacuum cleaner is
running (indicator lamp flashes or is
on *), pushing again = vacuum cleaner
goes out (indicator lamp goes out)

2 Pushbutton operation of the remote

control: pushing 1x = vacuum cleaner is
on (indicator lamp flashes or is on *), af-
ter expiration of the set operating time,
the vacuum cleaner shuts down (indica-
tor lamp goes out)

3 Switch operation of the remote control:

The vacuum cleaner runs as long as the
switch is on "on" (I).

* Indicator lamp flashes: B129-B135 = 1, in-
dicator lamp is on: B129-B135 = 0

Set parameters B020 to B030:
Specify the operating time of the vacu-
um cleaner at the relevant stations with
pushbutton operation of the remote
control.

Set parameter B033:
Specify maximum operating time of the
vacuum cleaner. This prevents a con-
tinuous operation of the vacuum clean-
er if no switch-off takes place via the
remote control.

Set parameters B049 to B052:
Specify the operating mode of the rele-
vant remote control.

Reset parameter B065:
Perform reset of the shift counter. In or-
der to do so, enter password (1234) or
simultaneously hold down the naviga-
tion keys (◄/►) for 2 seconds.

Set parameters B129 to B135:
The "indicator lamp" signal on the re-
mote control can also be used for con-
trolling valves, sliders, etc.

Set parameter B137:
Soft start yes/no

Set parameter B143:
Specify stopping time of the vacuum
cleaner. This way, the suction pipe is
vacuumed clear after closing all valves
or sliders.
Caution: When using this function, a
leak air flap must be installed to avoid
an excessive vacuum in the system.

Remote control with pushbutton

(option)

Remote control with switch (option)

Operating modes

1

1

Operation

Parameters of the PLC control

B020

With pushbutton operation of the
remote control: Operating time of
the vacuum cleaner on station 1
(specification in seconds)

B028

With pushbutton operation of the
remote control: Operating time of
the vacuum cleaner on station 2
(specification in seconds)