Changed settings, Changed settings -76, Admin settings] 3-76 changed settings – Konica Minolta bizhub C35 User Manual

Page 123

Advertising
background image

[Admin Settings]

3-76

Changed settings

For increased security, the following settings are set when enhanced security
settings are applied.

"

A changed setting cannot be changed when [Enhanced Security
Mode] is set to [OFF].

"

If password rules have been applied, a password that does not meet
the conditions of the password rules is considered a failed attempt
during authentication.

*1

Set to [AES/3DES] when [Enhanced Security Mode] is set to [OFF].

Administrator mode parameters

Changed settings

[Security Settings] - [Security Details]
- [Password Rules]

Set to [ON].

[Security] tab in PageScope Web
Connection - [Authentication Setting]
- [General Settings] - [Public Access]

Set to [Restrict].

[Security] tab in PageScope Web
Connection - [PKI Settings] - [SSL/
TLS Settings] - [SSL/TLS]

Set to [Enable].

[Security] tab in PageScope Web
Connection - [PKI Settings] - [SSL/
TLS Settings] - [Encryption Strength]

Set to [AES-256] or [AES-256,
3DES-168].

*1

[Network] tab in PageScope Web
Connection - [E-mail Settings] -
[S/MIME] - [E-mail Text Encryption
Method]

Set to [3DES], [AES-128], [AES-192]
or [AES-256].

*1

[Network] tab in PageScope Web
Connection - [FTP Settings] - [FTP
Server Settings] - [FTP Server]

Set to [Disable].

[Network] tab in PageScope Web
Connection - [SNMP Settings] -
[SNMP v1/v2c Settings] - [Write]

Set to [Disable].

[Network] tab in PageScope Web
Connection - [SNMP Settings] -
[SNMP v3 Settings] - [Write User
Name] - [Security Level], [auth-pass-
word] and [priv-password]

Set to [Auth-password/Priv-pass-
word].

[Security Settings] - [Security Details]
- [Registering and Changing Addr.]

Set to [Restrict].