33

Fault

Possible cause

Remedial action

The refrigerating unit

is switching on more

frequently and for

longer.

Appliance opened

frequently.

Do not open the appliance

unnecessarily.

The ventilation

openings have been

covered.

Remove obstacles.

Appliance is not

cooling, temperature

display and light

are lit.

Showroom mode is

switched on.

Hold down alarm button, Fig

2/1,

for 10 seconds until an

acknowledgement signal sounds.
After a short time check whether

your appliance is cooling.

The light does not

function.

The LED light

is defective.

See chapter “Light (LED)” section.

Appliance was open

too long.
Light is switched off

after approx. 10 min.

When the appliance is closed

and opened, the light is on again.

The freezer

compartment is too

warm.
Temperature display,

Fig.

2/4, is flashing.

Appliance opened

frequently.

Do not open the appliance

unnecessarily.

Too much food was

placed in the

compartment.

Switch on super freezing before

inserting the food.

Warning signal sounds

and the temperature

display flashes.
The freezer

compartment is too

warm! Frozen food is

at risk.

Freezer compartment

door is open.

See chapter entitled “Alarm

functions”.

Too much food was

placed in the freezer

compartment at once.

Advertising