Troubleshooting

1

The shaving heads do not move smoothly over

the skin.

Cause: not enough shaving gel/lotion has been

applied.

Press the pump button a few times until sufficient

NIVEA FOR MEN shaving gel/lotion has been

released to allow the shaving heads to move

smoothly over your face again.

2

Reduced shaving performance

Cause 1: the shaving heads are dirty.

The shaver has not been cleaned immediately after

use and/or has not been rinsed long enough and/or

the water used to rinse the shaver was not hot

enough.

Clean the shaver thoroughly before you continue

shaving. See chapter ‘Cleaning and maintenance’.

Cause 2: long hairs are obstructing the shaving

heads.

Press the release button to open the shaving unit.

Turn the wheel anticlockwise (1) and remove the

retaining frame (2).

Clean the cutters and guards.

Do not clean more than one cutter and guard

at a time, since they are all matching sets. If you

accidentally mix up the cutters and guards, it

may take several weeks before optimal shaving

performance is restored.

Remove the hairs with the brush supplied.

Put the shaving heads back into the shaving unit. Put

the retaining frame back into the shaving unit and

turn the lock clockwise.

-

-

-