16 throttle checks and adjustments - ford engine, Throttle checks, Throttle adjustments - in sequence – JLG 500RTS ANSI Service Manual User Manual

Page 27: 17 throttle checks and adjustments - deutz f3l1011, Throttle checks and adjustments - ford engine -11

Advertising
background image

SECTION 2 - PROCEDURES

3120696

– JLG Sizzor –

2-11

2.16 THROTTLE CHECKS AND

ADJUSTMENTS - FORD ENGINE

Throttle Checks

1.

Check that anti-dieseling solenoid is operating. If
solenoid is operating, an audible click should be
heard when the ignition is switched ON and OFF.

2.

Check throttle linkage for smooth operation by rotat-
ing throttle lever by hand to full throttle position, then
slowly back to idle position, feeling closely for stick-
ing or binding.

Throttle Adjustments - In Sequence

NOTE: Steps (1) and (2) are preliminary settings.

1.

Remove cover from controller. With engine shut
down, turn gain CCW as far as it will go, then turn
screw slot CW until vertical. Gain may need fine tun-
ing.

2.

Turn droop CCW as far as it will go. Then turn screw
slot CW until vertical. Droop should not need further
adjustment.

3.

Turn idle adjusting screw on carburetor CCW all the
way out CCW until there is a gap between the screw
and stop plate.

4.

Start engine and allow it to come up to operating
temperature.

5.

Remove wire from no. 7 connector on controller,
which will switch engine speed to HIGH. Adjust
speed screw until engine runs at 3000 rpm.

NOTE: If engine surges, turn gain screw one or two degrees

CCW until surging stops, no more.

6.

Replace wire no. 7 connector on controller, which
will return engine to LOW speed. Adjust remote until
engine runs at 2200 rpm.

7.

Recheck speeds. When satisfied, apply a drop of fin-
gernail polish to all trimpot screws. Replace cover.

2.17 THROTTLE CHECKS AND

ADJUSTMENTS - DEUTZ F3L1011

NOTE: Never run fuel tank dry. Diesel engines cannot be

restarted after running out of fuel until fuel system
has been air-vented or bled of air. (See Deutz Oper-
ators Manual for procedure).

1.

Disconnect actuator cable from the throttle lever.
With the aid of an assistant, start the engine and
allow it to come up to operating temperature. Adjust
throttle lever stop until engine runs at 2000 rpm.
Shut down engine. Reattach actuator cable to throt-
tle lever, making sure that low engine setting
remains the same. Restart engine and check set-
tings. If necessary, adjust slide pin to contact low
engine limit switch at 2000 rpm. Shut down engine.

2.

With the aid of an assistant, start engine from plat-
form and allow it to come up to operating tempera-
ture. Disconnect modular dump valve wire. Activate
HIGH ENGINE switch. Activate and Drive Controller
and hold it in full drive position. Adjust slide pin to
contact high engine limit switch at 3000 rpm. Shut
off all switches and controllers. Reconnect modular
control dump valve wire.

NOTE: Actuator cable travel must stop slightly before lever

makes contact with throttle lever stop. Failure to do
so will burn out actuator.