28 preventive maintenance and inspection schedule, Preventive maintenance and inspection schedule -30 – JLG 500RTS ANSI Service Manual User Manual

Page 46

Advertising
background image

SECTION 2 - PROCEDURES

2-30

– JLG Sizzor –

3120696

2.28 PREVENTIVE MAINTENANCE AND

INSPECTION SCHEDULE

a. The preventive maintenance and inspection

checks are listed and defined in the following
table. This table is divided into two basic parts,
the AREA to be inspected and the INTERVAL at
which the inspection is to take place. Under the
AREA portion of the table, the various systems
along with the components that make up that
system are listed. The INTERVAL portion of the
table is divided into five columns representing
the various inspection time periods. The num-
bers listed within the interval column represent
the applicable inspection code for which that
component is to be checked.

b. The checks and services listed in this schedule

are not intended to replace any local or regional
regulations that may pertain to this type of
equipment nor should the lists be considered as
all inclusive. Variances in interval times may
occur due to climate and/or conditions and
depending on the location and use of the
machine.

c. JLG Industries requires that a complete annual

inspection be performed in accordance with the
Annual Machine Inspection Report form. Forms
are supplied with each new machine and are
also available from JLG Customer Service. Form
must be completed and returned to JLG Indus-
tries.

NOTICE

JLG INDUSTRIES REQUIRES THAT A COMPLETE ANNUAL
INSPECTION BE PERFORMED IN ACCORDANCE WITH THE
ANNUAL MACHINE INSPECTION REPORT FORM.

NOTE: This machine requires periodic safety and mainte-

nance inspections by a JLG Dealer. A decal located
on the frame affords a place to record (stamp)
inspection dates. Notify dealer if inspection is over-
due.

d. The inspection and maintenance code numbers

are as follows:

1.

Check for proper and secure installation.

2.

Check for visible damage and legibility.

3.

Check for proper fluid level.

4.

Check for any structural damage; cracked
or broken welds; bent or warped surfaces.

5.

Check for leakage.

6.

Check for presence of excessive dirt or for-
eign material.

7.

Check for proper operation and freedom of
movement.

8.

Check for excessive wear or damage.

9.

Check for proper tightness and adjustment.

10. Drain, clean and refill.

11. Check for proper operation while pump/

motor is running.

12. Check for proper lubrication.

13. Check for evidence of scratches, nicks or

rust and for straightness of rod.

14. Check for condition of element; replace as

necessary.

15. Check for proper inflation.

16. Check Inspection Decal for current inspec-

tion stamp.

Advertising
This manual is related to the following products: