No power at platform control, Overview of procedure, Check for these obvious conditions first – JLG 20VP (3120728) Service Manual User Manual

Page 78: Battery voltage 24 volts. (fully charge batteries), Keyswitch is turned to plat. (platform), Table 3-5. no power at platform control, No power at platform control -18

Advertising
No power at platform control, Overview of procedure, Check for these obvious conditions first | Battery voltage 24 volts. (fully charge batteries), Keyswitch is turned to plat. (platform), Table 3-5. no power at platform control, No power at platform control -18 | JLG 20VP (3120728) Service Manual User Manual | Page 78 / 104 No power at platform control, Overview of procedure, Check for these obvious conditions first | Battery voltage 24 volts. (fully charge batteries), Keyswitch is turned to plat. (platform), Table 3-5. no power at platform control, No power at platform control -18 | JLG 20VP (3120728) Service Manual User Manual | Page 78 / 104