Epr assembly -67 – JLG 4394RT Service Manual User Manual

Page 103

Advertising
background image

SECTION 3 - CHASSIS & SCISSOR ARMS

3121133

– JLG Sizzor –

3-67

4.

Drop the magnet into the bottom of the filter hous-
ing.

5.

Install the filter into the housing.

6.

Install the retaining bolt into the filter housing.

7.

Install the filter up to the bottom of the electric lock
off.

8.

Tighten the filter retaining bolt to 106 in lbs (12 Nm).

9.

Open manual shut-off valve. Start the vehicle and
leak check the propane fuel system at each serviced
fitting Refer to Propane Fuel System Leak Test.

Electronic Pressure Regulator (EPR)
Assembly Replacement

The EPR assembly is a made up of two separate compo-
nents. The Voice Coil Section is not serviceable and can
only be replaced as an assembly. The pressure regulator
section is serviceable and will be detailed in this section.

REMOVAL

1.

Relieve the propane fuel system pressure. Refer to
Propane Fuel System Pressure Relief.

2.

Disconnect the negative battery cable.

3.

Slowly remove the fuel inlet fitting at the Electric
Lock Off.

NOTE: Residual vapor pressure will be present in the fuel

system.

4.

Disconnect the electrical connector to the Electric
Lock off .

5.

Remove the Electric Lock Off from the regulator.

6.

Remove the lock pin from the vapor fitting on the
regulator housing and remove the fitting and hose
and retain the pin.

7.

Remove the lock pin from the pressure sensor on
the regulator housing and remove the Sensor and
retain the pin.

8.

Using a clamp pliers pinch off the hoses on the cool-
ant lines to the regulator.

9.

Remove the lock pin from both the water fittings on
the regulator housing and remove the fittings and
hoses and retain the pin.

10.

Disconnect the EPR electrical connector.

11.

Remove the (3) three nuts from the EPR isolators
and the EPR mounting bracket.

12.

Remove the EPR from the bracket.

13.

Remove the (3) three mounting isolators.

INSTALLATION

NOTICE

DO NOT USE TEFLON TAPE ON ANY FUEL FITTING. USE A LIQ-
UID PIPE THREAD SEALANT WHEN INSTALLING FITTINGS.

CHECK ALL THE O-RINGS ON THE VAPOR AND WATER FIT-
TINGS FOR ANY DAMAGE REPLACE IF NECESSARY.

LUBE ALL THE O-RINGS WITH AN O-RING LUBE BEFORE
INSTALLING.

1.

Install the three (3) rubber isolators to the bottom of
the EPR.

2.

Install the EPR assembly to the bracket and tighten
the retaining nuts.

NOTE: Do not over tighten the isolators and cause a separa-

tion of the isolators.

3.

Install the fuel temperature sensor into the regulator
opening and lock in place with the locking pin, con-
nect the electrical connector.

4.

Insert the fuel vapor line and fitting into the regulator
port and lock in place with the locking pin.

5.

Install both the water hoses and fittings into the reg-
ulator and lock in place with the locking pin remove
the clamp pliers from the hoses.

6.

Install the electric lock off into the regulator inlet and
tighten into proper location, connect the electrical
connector.

7.

Connect the fuel supply line and tighten until fully
seated.

1. Pressure Regulator Section
2. Fuel Inlet
3. Coolant Passage

4. Primary Test Port
5. Secondary Test Port
6. Voice Coil Section

Figure 3-38. EPR Assembly