2 flash codes and descriptions, Fault code listing - software p1.x -6 – JLG 4394RT Service Manual User Manual

Page 160

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

5-6

– JLG Lift–

3121133

5.2 FLASH CODES AND DESCRIPTIONS

Table 5-1. Fault Code Listing - Software P1.X

Fault Flash

Code

Communicated (Displayed on Analyzer) Fault

Description

Priority

None

No flash code is indicated for the following help
messages. They are intended to hint at a possible
problem if the vehicle is not behaving as expected.

1

FUNCTION SELECTED BUT TRIGGER SWITCH OPEN

Reported when the trigger is not closed with function selected
and joystick out of center.

RUNNING AT CUTBACK – ABOVE ELEVATION

Reported any time the machine is considered to be above ele-
vation.

ACCESSORY FAULT

Reports when CAN faults are reported by an accessory mod-
ule.

FRONT LEFT LEVELING JACK AT END OF STROKE

Reported when the front left leveling jack is reported to be at the
end of stroke pressure.

FRONT RIGHT LEVELING JACK AT END OF STROKE

Reported when the front right leveling jack is reported to be at
the end of stroke pressure.

REAR LEFT LEVELING JACK AT END OF STROKE

Reported when the rear left leveling jack is reported to be at the
end of stroke pressure.

REAR RIGHT LEVELING JACK AT END OF STROKE

Reported when the rear right leveling jack is reported to be at
the end of stroke pressure.

LEVELING JACK SET PREVENTED - ECM LOST

Reported when autoleveling is not available when communica-
tion with the ECM times-out.

GENERATOR PREVENTED - ECM LOST

Reported when generator is not available when communica-
tion with the ECM times-out.

DRIVE PREVENTED - ECM LOST

Reported when elevated drive is not available when communi-
cation with the ECM times-out.

ELEVATION SENSOR DISAGREEMENT

Reported when elevation prox switch is closed when the 26 ft
(3394RT) or 30 ft (4394RT) voltage is reached on the elevation
angle sensor. (prevents further lift up from platform controls)

2/1

Flash code 2/1 indicates issues at power up.

2

KEYSWITCH FAULTY – PLATFORM & GROUND ACTIVE
TOGETHER

Reported when the ground module is reading both ground and
platform modes are selected by the keyswitch. The control
system defaults control to ground mode.