word to advance to a lower level. This ensures that a set-
ting cannot be accidentally altered. To change the access
level, the correct password must be entered. To enter the
password, scroll to the ACCESS LEVEL menu. For exam-
ple:

MENU:

ACCESS LEVEL 2

Press ENTER to select the ACCESS LEVEL menu.

Using the UP or DOWN arrow keys, enter the first digit of
the password, 3.

Then using the RIGHT arrow key, position the cursor to
the right one space to enter the second digit of the pass-
word.

Use the UP or DOWN arrow key to enter the second digit
of the password which is 3.

Repeat this process until you have entered all five digits of
the password which is 33271.

Once the correct password is displayed, press ENTER.

The access level should display the following, if the pass-
word was entered correctly:

MENU:

ACCESS LEVEL 1

Repeat the above steps if the correct access level is not
displayed or you can not adjust the personality settings.

Adjusting Configuration Using the Hand
Held Analyzer on All 1600289 Controllers:

Once you have gained access to level 1, and a personality
item is selected, press the UP or DOWN arrow keys to
adjust its value, for example:

PERSONALITIES:

DRIVE ACCEL 1.0s

There will be a minimum and maximum for the value to
ensure efficient operation. The value will not increase if the
UP arrow is pressed when at the maximum value nor will
the value decrease if the DOWN arrow is pressed and the
value is at the minimum value for any particular personal-
ity. If the value does not change when pressing the up and
down arrows, check the access level to ensure you are at
access level 1.

When a machine digit item is selected, press the UP or
DOWN arrow keys to adjust its value, for example:

GROUND ALARM:

2=DRIVE

The effect of the machine digit value is displayed along
with its value. The above display would be selected if the
machine was equipped with a ground alarm and you

wanted it to sound when driving. There are certain set-
tings allowed to install optional features or select the
machine model.

When selecting the machine model to match the size of
the machine, the personality settings will all default to the
factory recommended settings. Note: Refer to the appro-
priate Machine Personality Settings Table, and the
Machine Setup Table in the JLG Service Manual for the
recommended factory settings. Refer to the JLG part
number of the controller, printed on the front label, to
select the correct table in the manual.

NOTE: Password 33271 will give you access to level 1,

which will permit you to change all machine person-
ality settings. There are some settings that JLG
strongly recommends that you do not change. These
settings are so noted below:

ELEVATION CUTBACK

POSITRAC TIMEOUT

HIGH DRIVE CURRENT LIMIT

HIGH DRIVE TIME LIMIT

CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE
PERFORMANCE OF YOUR MACHINE.

WHEN INSTALLING A NEW SMART SYSTEM CONTROLLER ON
THE MACHINE, ELECTRICAL SILICONE GREASE, JLG PART
NUMBER 0100076 OR 7016397, MUST BE APPLIED TO THE BACK
OF THE CONTROLLER.

IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELEC-
TRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. REC-
OMMENDS A MAXIMUM PRESSURE OF 52 BAR (750 PSI) AT A
MINIMUM DISTANCE OF 30.5 CM (12 IN) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS
ARE SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR
BRIEF TIME PERIODS TO AVOID HEAVY SATURATION.