Platform control station – JLG 2658E3 Operator Manual User Manual

Page 23

Advertising
background image

SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL

3120877

– JLG Sizzor –

3-3

6. Powered Deck Extension Switch (If Equipped -

Models 2033E3, 2046E3, 2646E3, and 2658E3 Only)
If the machine is equipped with either the 1.2 m or
1.8 m hydraulically-powered deck extension, this
three-position, momentary contact toggle switch
provides extension or retraction of the deck exten-
sion when positioned to extend or retract.

NOTE: If the machine is equipped with a powered deck

extension and the optional fold-down rails, the rails
must be in the upright position before retracting the
power deck extension.

Platform Control Station

1. Emergency Stop Switch - A two-position, red,

mushroom-shaped emergency stop switch func-
tions to provide power to the platform control station
and also to turn off power to the platform function
controls in the event of an emergency. With the
power selector switch positioned to platform, power
is turned on by pulling the switch out (on), and is
turned off by pushing the switch in (off). Turning the
emergency stop switch off and then on again will

reset the smart system if a system fault has occurred
and the machine has shut down.

2. Membrane Switch Panel - The function switches at

the platform control station are an integral part of a
membrane switch panel, which contains switches
for drive, high drive, lift, powered deck extension (if
equipped), and posi-trac, plus a red tilt indicator
light (if equipped). The drive, lift and powered deck
extension function switches have a small green light
indicator beside them which is illuminated when that
function is active. The function switch light indicators
will flash once or twice, then go out, when the plat-
form emergency stop switch is turned on. If the light
indicators fail to flash or if they fail to stop flashing,
re-cycle the emergency stop switch. To activate the
drive, lift, and powered deck functions, press the
applicable function switch, then activate the joystick
within three seconds to operate the function. If the
joystick is not activated within three seconds, power
is turned off to the function switch and the switch
must be pressed again. The posi-trac and high drive
functions are used in conjunction with the drive func-
tion. Do not try to operate the drive, lift, and powered
deck extension functions simultaneously. If the drive,
lift, and powered deck extension functions are

Figure 3-1. Ground Control Station - Models 1532E3/1932E3

Advertising