Start battery, Engine starter, Start control relay – JLG M400 Service Manual Service Manual User Manual

Page 105

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3121827

– JLG Lift –

3-63

Start Battery

The RBS requires a 12V lead-acid start battery (not sup-
plied with the system), which provides starting power and
power for the RBS controls.
This battery is charged by the engine dynamo and
dynamo regulator when the engine is running.

Engine Starter

The engine is equipped with a 12VDC starter, which pro-
vides the mechanical power to crank the engine. Electrical
power for the starter is provided by the start battery.
The starter is energized by the start control relay.

Start Control Relay

The start control relay energizes the solenoid of the
engine starter and the pull coil of the engine fuel solenoid.
The start control relay is energized by the engine/genera-
tor controller from pin J2-4.
The start control relay is located on the fuel solenoid
bracket on the right side of the engine.

Advertising
This manual is related to the following products: