Adjusting parameters using the hand held analyzer, Machine setup – JLG M400 Service Manual Service Manual User Manual

Page 185

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121827

– JLG Lift –

6-5

Adjusting Parameters Using the Hand Held
Analyzer

Once you have gained access to level 1, and a personality
item is selected, press the UP or DOWN arrow keys to
adjust its value, for example:

PERSONALITIES:
DRIVE ACCEL 1.0s

There will be a minimum and maximum for the value to
ensure efficient operation. The Value will not increase if
the UP arrow is pressed when at the maximum value nor
will the value decrease if the DOWN arrow is pressed and
the value is at the minimum value for any particular per-
sonality. If the value does not change when pressing the
up and won arrows, check the access level to ensure you
are at access level 1.

Machine Setup

When a machine digit item is selected, press the UP or
DOWN arrow keys to adjust its value, for example:

GROUND ALARM:
2 = DRIVE

PERSONALITIES:
DRIVE ACCEL 1.0s

GROUND ALARM:
2=DRIVE

Advertising