6 positrac/tilt module, Positrac/tilt module -19, Drive components -19 – JLG M400 Service Manual Service Manual User Manual

Page 61

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3121827

– JLG Lift –

3-19

3.6 POSITRAC/TILT MODULE

When installing a new positrac/tilt module, always ensure
that it is calibrated using the JLG Control System analyzer
before operating the machine. Refer to JLG Control Sys-
tem Analyzer Kit instructions. Use a standard bubble level
in two different directions to ensure that the machine’s
frame is level prior to installing the new positrac/tilt mod-
ule.

1. Place the machine on a flat, level surface. Check for

level by placing a bubble level on the frame in both
directions.

2. Plug in the analyzer (Analyzer - p/n 1600244, Cable -

p/n 1600633) into port J9 on the power module or
port J1 on the platform module.

3. Use the right arrow key to curse over to “ACCESS

LEVEL 2". Depress Enter.

4. Use Up/Down arrow keys to enter the following

password “33271”. Depress Enter.

5. Use the right arrow key to curse over to “LEVEL

VEHICLE”. Depress Enter. Depress Enter again.

6. Verify that the tilt reading is now “0.0; 0.0".

TO ASSURE PROPER OPERATION, THE MACHINE MUST BE LEVEL
WHEN INSTALLING AND CALIBRATING A NEW POSITRAC/TILT
MODULE.

Figure 3-8. Drive Components

Advertising
This manual is related to the following products: