10 valves and manifolds, 1 main control valve, Valves and manifolds – JLG G6-23A Service Manual User Manual

Page 81: Main control valve

Advertising
background image

8.11

G5-19A, G6-23A

Hydraulic System

8.10

VALVES AND MANIFOLDS

8.10.1

Main Control Valve

The main control valve is mounted on the rear of the
machine behind the rear access panel.

The main control valve assembly consists of various
working sections with their own valve assemblies, each
providing a specific hydraulic function. The section
assemblies are the outlet, extend/retract (1), auxiliary (2),
tilt (3), lift/lower (4) and load sense outlet sections.

a. Main Control Valve Removal

1. Park the machine on a firm, level surface, fully

retract the boom, lower the boom, place the
transmission control lever in (N) NEUTRAL, engage
the park brake and shut the engine OFF.

2. Place an Do Not Operate Tag on both the ignition

key switch and the steering wheel, stating that the
machine should not be operated.

3. Remove the rear panel. Allow the hydraulic fluid to

cool.

4. Thoroughly clean the main control valve and

surrounding area, including all hoses and fittings,
before proceeding.

5. Place a suitable container to catch hydraulic fluid

drainage beneath the frame.

6. Label, disconnect and cap all the hydraulic hoses

attached to the main control valve. Cap all fittings
and openings to keep dirt & debris from entering the
hydraulic system.

7. Wipe up any hydraulic fluid spillage in, on, near and

around the machine and the work area.

8. Remove the four bolts securing the main control

valve to the frame bracket.

b. Main Control Valve Disassembly

1. To disassemble the individual sections of the main

control valve, remove the nuts from the end of the tie
rod. Pull the tie rods out through the sections.

2. Disassemble each section assembly as required.

Some sections include a pre-adjusted relief valve that
regulates pressure in a specific circuit.

IMPORTANT: DO NOT adjust any of the relief valve
assemblies! Tampering with a relief valve will irrevocably
alter pressure in the affected circuit, requiring recalibration
or a new relief valve.

Disassemble each Valve Section

1. Carefully separate the load sense outlet section from the

crowd section.

2. Remove the o-rings from between the two sections.

3. Carefully separate each remaining section being

careful not to lose the load sense shuttle ball.

4. Remove both end caps from each end of the valve

sections then remove each control spool.

5. Remove any check valves, compensator valves,

anti-cavitation valves or shock valves from each
individual valve section if equipped.

6. Keep all parts being removed from individual valve

sections tagged and kept together.

c. Main Control Valve Parts Cleaning

Clean all components with a suitable cleaner, such as
trichlorethylene, before continuing. Blow dry.

MAH0120

1

2

3

4

FRONT OF MACHINE

MAH0720

Valve Section