Single supply, Separate auxiliary supply – ElmoMC SimplIQ Digital Servo Drives-Whistle Installation Guide User Manual
Page 28
Advertising

Whistle and Tweeter Installation Guide
Installation
MAN-WHTWIG (Ver. 1.604)
28
3.8.1.
Single Supply
A single isolated DC power supply can provide power for both the main power and the Auxiliary
(Drive Logic) Supply in up to 100 V models. The drawing below shows how a single supply is
connected.
Figure 8: Single Supply for both the Main Power Supply and
the Auxiliary Supply in Up to 100 V Models
Note:
For 200 V models, it is forbidden to connect VL to VP+. Two separate power supplies are
required
3.8.2.
Separate Auxiliary Supply
Power to the Auxiliary Supply can be provided by a separate Auxiliary Supply.
Figure 9: Separate Auxiliary Supply Connection Diagram