4 dip switch settings, 1 dip switch s1, 2 dip switch s2 – EUCHNER EKS FSA with Ethernet Interface User Manual

Page 14: Dip switch settings, Dip switch s1, Dip switch s2

Advertising
background image

Manual EKS Electronic-Key Adapter Ethernet

4.4 DIP switch settings

The device has three DIP switches (S1, S2, S3).

DIP switch

Function

S1

(4-fold)

S1.1 … S1.4; write and read settings

S2

(8-fold)

S2.1 … S2.8; setting of a fixed DNS name (required only for special applications)

S3

(4-fold)

S3.1 …S3.4; settings for network connection and service

Information!

The settings are only applied when the power supply is switched on.

4.4.1 DIP switch S1

DIP

switch

Function

Factory setting

S1.1

ON = write protection for read/write Electronic-Key

OFF

S1.2 No

function

OFF

S1.3 No

function

OFF

S1.4 No

function

OFF

Information!

It is imperative that all DIP switches without a function (S1.2, S1.3 and S1.4) are set to OFF! In this
way problems with any functions added in the future will be avoided.

4.4.2 DIP switch S2

DNS

name

LSB
S2.1

S2.2

S2.3

S2.4

S2.5

S2.6

S2.7

MSB

S2.8

EKS000

OFF OFF OFF OFF OFF OFF OFF OFF

EKS001

ON OFF OFF OFF OFF OFF OFF

OFF

EKS002

OFF ON OFF OFF OFF OFF OFF OFF

EKS003

ON ON OFF OFF OFF OFF OFF OFF

… … … … … … … … …

EKS254

OFF ON ON ON ON ON ON ON

EKS255

ON ON ON ON ON ON ON ON

Information!

All DIP switches S2 are relevant only in conjunction with the Siemens SINUMERIK DHCP address
assignment (see section 6.1.1.3 Operation in the Siemens system network).

Page 14/40

Subject to technical modifications

100420-02-01/09

Advertising