6.2 Connection of power supply

(For information on pin assignment see section 4.3.2 Plug-in screw terminals for power supply)

It is imperative that the following points are observed:

f The connections must be made as appropriate to maintain EMC performance.

f A power supply of suitable EMC performance must be used for the power supply.

f Conductor cross-section maximum 1.5 mm².

f Tighten the terminal screws on the plug to 0.22 Nm.

6.3 Connection of function earth

The function earth is connected via terminal 3 on the plug-in screw terminals for the power supply. This
connection is electrically connected internally to the housing of the Electronic-Key adapter.

Information!

The function earth must be connected to PE!

6.4 Connection of the switched outputs (for EKS FSA only)

Incorrect connection or errors in the safety-related integration of the EKS FSA can lead to fatal injury.
For this reason, observe the following safety aspects:

Warning!

f It is not possible to generate a safe signal by using only the switched outputs LA1/LA2 and LB1/LB2.

Safe, downstream evaluation is always necessary (e. g. using a safety relay). Use of the switched
output LB1/LB2 as an alternative to the data wire is optional.

f The safe evaluation must always be dual-channel. For this purpose, there are two alternatives:

1. Evaluation of output LA1/LA2 as channel LA together with an evaluation of the data wire as

channel LB (recommended)

2. Evaluation of output LA1/LA2 as channel LA together with the output LB1/LB2 as channel LB

f Integrate the EKS FSA as defined in the following connection examples from EUCHNER.