(-06)
Headache Rack
Frame
Flange To Rear
(-05)
Angle Clamp
(f)
(g)
(h)
(i)
(k)
(m)
Hole A
Hole B
DETAIL B
(-01) / (-02)
Foot Plates
K
DETAIL C
STEP 1:
Set right and left side foot plates (-01)(-02) onto bed rail with short flange facing
down and front edge of flange contacting front of bed. Next check the location
of hole A & B in foot plate against stake pocket centers. Choose the hole that
best mates per DETAIL B and insert flat head bolt (g) from top then start threads
into stake pocket "T" nut (i).
STEP 2:
Insert square neck flat head bolts (h)
through square hole in foot plates.
Start threads with nut (k) to hold in
place while foot plate is being ad-
justed to final position. It may be
neccessary to angle bolt (g) to slip "T"
nut (i) through stake pocket opening
per DETAIL C. Once in place with
front flange of foot plates (-01)(-02)
firmly against front of bed tighten
bolt (g) using included wrench. Now
insert bolt (f) through the welded
tube and screw into angle clamp
(-05)with flange to the inside and up.
For TECHNICAL SUPPORT CALL: 800-343-7486