Installation 4-6

4.3

Cooling Water Connections

Specifications

The differential pressure required between the water inlet and outlet
connections is 30 to 45 psid (0.2 to 0.3 MPa). The maximum allowable
water pressure is 120 psi (0.83 MPa). The water supply must be capable of
providing water flow at a rate indicated in Table 1-1. See Table 1-2 for the
maximum cooling water heat load.

Water connections

To connect the water supply and drain to the heat exchanger water
connections , use a 1.5 in. (38 mm) water service hose for the 506.82 HPU.
Use a 2 in. (50.8 mm) water service hose for the 506.92 HPU.

water out

water in

hot fluid - from supercharge pump

cold fluid - to low pressure filter

VW-G055

Heat Exchanger – Top View

water

regulating

valve