Section 5 theory of operation, 1 hydraulic operation – MTS Hydraulic Power Unit Model 506-92 User Manual

Page 38

Advertising
background image

Theory of Operation 5-1

Section 5

Theory of Operation

This section describes the hydraulic and electrical operation of Model
506.82/.92 Hydraulic Power Unit (HPU).

5.1

Hydraulic Operation

The figure below is a block diagram of the HPU hydraulic operation.

3 micron
fine filter

filter bypass
50 psi
(0.34 MPa)

supercharge
pump

fluid level/temperature gage

water out

standard
water
regulating
valve

water in

optional
water
shut-off
solenoid
valve

pressure

-24 JIC

pressure

-32 4 bolt

pressure

gage

pressure

accumulator

backup relief valve
3500 psi (25 MPa)

return

-24 JIC

return

-32 4 bolt

slow turn-on
accumulator

outlet filter

10 micron

outlet filter

10 micron

main manifold
assembly

check valve

check valve

pump 1 – compensator
set at 3000 psi (21 MPa)

pump 2 – compensator
set at 3050 psi (21 MPa)

low inlet pressure switch

supercharge relief valve –
cracks at 30 psi (0.2 MPa)

filter pressure
switch
35 psi
(0.24 MPa)

supercharge and
manifold filter

heat
exchanger

water shut-off solenoid

valve switch – 100

°

F

(38

°

C) rising

over-temperature
switch – 140

°

F

(60

°

C) rising

low fluid level
float switch

3Sol

24 Vdc

2Sol

1Sol

1PS

2PS

24 Vdc

20 psi (0.14 MPa)

1FS

VW-C038

4Sol

Figure 5-1. Hydraulic Block Diagram