Replacing the Return Line Filter

Model 505.07/.11 SilentFlo™ HPU

Maintenance

59

5. Check and adjust the hydraulic fluid delivery system so that:

Hydraulic fluid temperature stabilizes within the parameters given in
the Specifications table when the HPU is operating at high pressure.

Pressure line reading is maintained at 21 MPa (3000 psi) maximum
static value.

Maximum drain line back pressure is limited to 0.1 MPa (15 psi).

If you need to adjust the water-regulating valve, overtemperature switch or
pressure control valves, see the procedure for Changing the Water Flow.

Replacing the Return Line Filter

The filter element of the HPU should be replaced for the following reasons:

When the dirty-filter indicator lights

Whenever the hydraulic fluid is changed

The maximum interval recommended by the filter manufacturer has passed
(1000 hours or 6 months)

Prerequisite

You will need a filter element (MTS part number 100-009-495) or a filter kit
(MTS part number 100-030-195).

Procedure

To change the filter element:

Note

The dirty-filter indicator may light when the HPU is first started due to low
hydraulic fluid temperature. When the HPU is at normal operating
temperature, recheck the indicator to determine if the element actually
needs replacement.

1. Turn off the HPU.