Model 505.60 - 505.180 SilentFlo™ HPU

52

Model 505.60 HPU Setup

Installation

7. Connect the controller cable (if used).

The controller cable provides a means to connect a remote controller to the
HPU. When connected, your controller can remotely start and stop the unit
and switch between the low and high pressure selections. The cable also
permits the controller to monitor the low level, over temperature, and dirty
filter status. For information about the connection, see the appropriate
electrical schematics.

Note

If a controller is not used, the installed jumper plug must be used or the
unit will not start.

Model 505.60 HPU Setup

The following procedure should only be performed at HPU installation to verify
settings, when you replace the user interface panel, or if you need to change a
selection.

1. Rotate the power disconnect switch to the on (|) position.

When you apply power to the HPU the startup screen displays on the user
interface panel.

2. Verify that the platform displayed corresponds with the HPU model you are

installing.

505.60/.90 Selected—for a Model 505.60 or 505.90 HPU.

505.120/.150/.180 Selected—for a Model 505.120 or 505.150 or
505.180 HPU.

If the displayed platform is not correct, press and hold the platform selection
button until the selection changes (5 seconds).