Operator’s panel, Main screen – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-180 User Manual

Page 50

Advertising
background image

Operator’s Panel

Main Screen

The Main screen is displayed initially when the HPU is powered up. The following table describes the
pushbuttons and indicators on the Main screen.

Main Screen

Description

Name and Location

Indicator. Indicate the various state of the HPU

Faulted/Ready/Running/High
Pressure/Alarm/Overtemp Bypass

Faulted - red: Indicates when an interlock has occurred and
the HPU has been shut down.

Ready - green: Indicates the interlocks are cleared and the
HPU is ready to start.

Running - green: Indicates the HPU is running in low pressure.

High Pressure - green: Indicates at least one pump motor is
running in high pressure.

Alarm - yellow: Indicates a filter is dirty and needs attention.

Overtemp Bypass - yellow: Indicates an over temperature
interlock has occurred and the HPU has been put into a bypass
mode to circulate hydraulic fluid through the heat exchanger
until the hydraulic fluid level reaches an acceptable
temperature,

50 Series 505G2 SilentFlo™ Hydraulic Power Unit Product Information

Operation

Advertising