Windows ® 95/98/me/2000/xp ftp/ipp troubleshooting, Windows, 95/98/me/2000/xp ftp/ipp troubleshooting – Brother NC8100H User Manual

Page 138

Advertising
background image

CHAPTER 13 TROUBLESHOOTING

13-12

Windows

®

95/98/Me/2000/XP FTP/IPP

Troubleshooting



Want to use a different Port number other than 631
If you are using Port 631 for IPP printing, you may find that your
firewall may not let the print data through. If this is the case, use a
different port number (port 80), or configure your Firewall to allow
Port 631 data through.

To send a print job using IPP to a printer using Port 80 (the standard
HTTP port) enter the following when configuring your Windows

®

2000/XP system.

http://ip_address/ipp

Get More Info option in Windows

®

2000/XP not working

If you are using a URL of:

http://ip_address:631

or

http://ip_address:631/ipp

, the “Get More Info” option

in Windows

®

2000 will not function. If you wish to use the “Get

More Info” option use the following URL:

http://ip_address

This will then force Windows

®

2000 to use Port 80 to communicate

with the Brother Print / Fax server.

Windows

®

95/98/Me clients not able to get the driver from a

Windows

®

2000/XP system.


You must be using version 4.0 or later of Internet Explorer and the
“Microsoft Internet Print Services” software must be installed on
your client computers.

Advertising