Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 223

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

223

Supplemental Drive Information

Appendix A

Frame A and B Recommended Field Circuit Fuses

Field circuit fuses are internally mounted and provided with the drive. See Fuse
Code FS3 in

Figure 62

on page

219

. Also, see

Figure 63

on page

224

and

Figure 63

on page

224

for fuse locations.

Table 52 - 230V AC Input Drives

Table 53 - 460V AC Input Drives

Fram

e

Drive
Current
Rating
Code

Field
Amps

Type

Quantity Bussmann

Ferraz Shawmut
(Gould Shawmut)

SIBA

A

7P0

10

6 x 32 mm

2

FWH-016A6F

E085449

70 125 40.16

9P0
012
020
029
038
055
073

14

093
110

B

146

20

10 x 38 mm

2

FWC-25A10F

A60Q25-2

60 033 05.25

180
218
265
360
434

Fram

e

Drive
Current
Rating
Code

Field
Amps

Type

Quantity

Bussmann

Ferraz Shawmut
(Gould Shawmut)

SIBA

A

4P1

10

6 x 32 mm

2

FWH-016A6F

E085449

70 125 40.16

6P0
010
014
019
027
035
045
052
073

14

086
100
129

B

167

20

10 x 38 mm

2

FWC-25A10F

A60Q25-2

60 033 05.25

207
250
330
412

Advertising