Configure the module switches – Rockwell Automation 1756-DHRIO_DHRIOXT ControlLogix Data Highway Plus-Remote I/O Communication Interface Module User Manual

Page 68

Advertising
background image

68

Rockwell Automation Publication 1756-UM514C-EN-P - June 2014

Chapter 5

Messaging Between PLC-5 and SLC 5/04 Controllers

DH+ Messaging: PLC-5
Controllers with One 1756-
DHRIO

This application sends a DH+ message from PLC-5 controller A through a
1756-DHRIO module to PLC-5 controller B. Remote DH+ messaging is
required to send the message.

The following figure illustrates the steps you must follow in this application.

Configure the Module Switches

In this example, Channel A and Channel B on the 1756-DHRIO and
1756-DHRIOXT modules must be set for DH+.

Configure a Routing Table for the 1756-DHRIO Module

Use RSLinx to configure a routing table for the modules as shown in the
following figure.

ControlLogix
Chassis

1756-DHRIO

PLC-5/25 Controller A
Node Number: 015

DH+ Link
Link ID 1

PLC-5 Controller B
Node Number: 025

41363

Channel A
Node Number: 010

Channel B
Node Number: 020

DH+ Link
Link ID 2