Rockwell Automation 1746-HSCE2 Multi-Channel High Speed Counter Module User Manual
Page 81
Advertising
Publication 1746-UM002B-EN-P - August 2004
Configuration and Programming 4-31
Table 4.16 Class 4, Mode 3 Default Values
Parameter
Counter 1
Counter 2
Counter 3
Counter 4
Debug Mode Selection
Inactive
Range Allocation
4
4
4
4
Counter Type
Ring
Ring
Ring
Ring
Input Configuration
Pulse/Internal
Pulse/Internal
Pulse/Internal
Pulse/Internal
Gate/Preset Mode
No Preset
No Preset
No Preset
No Preset
Minimum Count
-8,388,607
-8,388,607
-8,388,607
-8,388,607
Maximum Count
+8,388,607
+8,388,607
+8,388,607
+8,388,607
Minimum Rate
-1,000,000
-1,000,000
-1,000,000
-1,000,000
Maximum Rate
+1,000,000
+1,000,000
+1,000,000
+1,000,000
Preset Value
0
0
0
0
All Output Ranges
Not programmed.
Interrupt Enable
Interrupt disabled.
Rate Value Format
Integer
Advertising