12 InView Marquee Message Display

4. Use chains (not supplied) to hang the signs from the ceiling.

Mounting Instructions
2706-P72 and 2706-P74
series NEMA 4 and 4x
models

1. Attach the two sign brackets to a wall, ceiling, or other surface.

Be sure to place the brackets so the bracket flanges face
appropriately as shown below. Mount the brackets the following
distance apart (measured from the center of the mounting holes
in each bracket):

2. Mount the sign on the sign brackets using the two large hex

bolts supplied.

Second
sign

First
sign

Second
mounting
bracket

First
mounting
bracket

Mounting
brackets

Second
sign

First
sign

TIP

Use chains capable of supporting 4 times the total
weight of the signs.

Wall
or
ceiling

Sign brackets, facing
in behind the sign

Sign brackets, facing
out from the sign

Mounted so flanges are hidden behind the sign

2706-P72CNx: 41.25 in (104.8 cm)

2706-P74CNx: 65.25 in (165.8 cm)

Mounted so flanges show on the sides of the sign

2706-P72CNx: 43.5 in (110.5 cm)

2706-P74CNx: 67.5 in (171.4 cm)

TIP

Do NOT install the sign directly to drywall or
plasterboard. The sign must be fastened to a surface
capable of supporting at least four times the weight
of the sign.

Advertising