Chapter 4
Using the Remote I/O Link

4–25

Rung 2:3
THE DATA LOCATION THIS BTR WILL READ IS DEFINED ON RUNG 0.
| BTR WIN 1 |
| MOVE WIN 1| CONFIG |
| UP |BTR ENABLE|BTW ENABLE DATA. |
| B3 N7:100 N7:110 +BTR––––––––––––––––––––+ |
+–+–––] [––––+–––]/[––––––––]/[–––––––––––––––––+BLOCK TRNSFR READ +–(EN)–+
| | 1 | 15 15 |Rack 02| |
| |MOVE WIN 1| |Group 0+–(DN) |
| |DOWN | |Module 0| |
| | B3 | |Control Block N7:100+–(ER) |
| +–––] [––––+ |Data file N7:0| |
| 2 |Length 0| |
| |Continuous N| |
| +–––––––––––––––––––––––+ |

Rung 2:4
SUBTRACT 20 FROM THE Y LOCATION VALUE OF THE WINDOW TO MOVE THE WINDOW UP 20
PIXELS.
| |MOVE WIN 1 WIN 1 Y |
| BTR DONE |UP LOCATION |
| N7:100 B3 +SUB–––––––––––––––+ |
+––––] [––––––––] [–––––––––––––––––––––––––––––––––––––––+SUBTRACT +–+
| 13 1 |Source A N7:4| |
| | 120| |
| |Source B 20| |
| | | |
| |Dest N7:4| |
| | 120| |
| +––––––––––––––––––+ |

Rung 2:5
ADD 20 TO THE Y LOCATION VALUE OF THE WINDOW TO MOVE THE WINDOW DOWN 20 PIXELS.
| |MOVE WIN 1 WIN 1 Y |
| BTR DONE |DOWN LOCATION |
| N7:100 B3 +ADD–––––––––––––––+ |
+––––] [––––––––] [–––––––––––––––––––––––––––––––––––––––+ADD +–+
| 13 2 |Source A N7:4| |
| | 120| |
| |Source B 20| |
| | | |
| |Dest N7:4| |
| | 120| |
| +––––––––––––––––––+ |

Rung 2:6
| BTR DONE LAST BLOCK |
| N7:100 O:023 |
+––––] [–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––(L)–––––+
| 13 03 |