STEP 14 Wire the Safety Reversing Sensors (continued)

OPTION B

PRE-WIRED INSTALLATION

1. Cut the end of the safety reversing sensor wire, making sure there is enough wire to reach the

pre-installed wires from the wall.

2. Separate the safety reversing sensor wires and strip 7/16 inch (11 mm) of insulation from each

end. Choose two of the pre-installed wires and strip 7/16 inch (11 mm) of insulation from each
end. Make sure that you choose the same color pre-installed wires for each sensor.

3. Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors

correspond for each sensor. For example, the white wire would connect to the yellow wire and
the white/black wire would connect to the purple wire.

4. At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end of the wires

previously chosen for the safety reversing sensors. Twist the like-colored wires together.

5. Insert the wires connected to the white safety sensor wires to the white terminal on the garage

door opener. Insert the wires that are connected to the white/black safety sensor wires to the
grey terminal on the garage door opener.

Safety reversing
sensor wires

Pre-installed
wires

White

White/Black

Yellow (for example)

Purple (for example)

Not Provided

Pre-installed wires

Safety reversing
sensor wires

7/16" (11 mm)

Yellow

Purple

1

3

4

7/16"

(11 mm)

2

WHITE

WHITE

RED

GREY

Purple

(for
example)

Yellow

(for example)

To insert or remove the wires from
the terminal, push in the tab with a
screwdriver tip.