ASCII Command

Hex Command

Function

P64Z118Q

50 36 34 5A 31 31 38 51

Monitor 1, Cam 1, 15 Seconds

P64Z128P

50 36 34 5A 31 32 38 50

Monitor 1, Cam 2, 15 Seconds

P64Z138O

50 36 34 5A 31 33 38 4F

Monitor 1, Cam 3, 15 Seconds

P64Z148N

50 36 34 5A 31 34 38 4E

Monitor 1, Cam 4, 15 Seconds

P64Z117R

50 36 34 5A 31 31 37 52

Monitor 1, Cam 1, 10 Seconds

P64Z127Q

50 36 34 5A 31 32 37 51

Monitor 1, Cam 2, 10 Seconds

P64Z137P

50 36 34 5A 31 33 37 50

Monitor 1, Cam 3, 10 Seconds

P64Z147O

50 36 34 5A 31 34 37 4F

Monitor 1, Cam 4, 10 Seconds

P64Z116S

50 36 34 5A 31 31 36 53

Monitor 1, Cam 1, 7.5 Seconds

P64Z126R

50 36 34 5A 31 32 36 52

Monitor 1, Cam 2, 7.5 Seconds

P64Z136Q

50 36 34 5A 31 33 36 51

Monitor 1, Cam 3, 7.5 Seconds

P64Z146P

50 36 34 5A 31 34 36 50

Monitor 1, Cam 4, 7.5 Seconds

P64Z115T

50 36 34 5A 31 31 35 54

Monitor 1, Cam 1, 5 Seconds

P64Z125S

50 36 34 5A 31 32 35 53

Monitor 1, Cam 2, 5 Seconds

P64Z135R

50 36 34 5A 31 33 35 52

Monitor 1, Cam 3, 5 Seconds

P64Z145Q

50 36 34 5A 31 34 35 51

Monitor 1, Cam 4, 5 Seconds

P64Z114U

50 36 34 5A 31 31 34 55

Monitor 1, Cam 1, 4 Seconds

P64Z124T

50 36 34 5A 31 32 34 54

Monitor 1, Cam 2, 4 Seconds

P64Z134S

50 36 34 5A 31 33 34 53

Monitor 1, Cam 3, 4 Seconds

P64Z144R

50 36 34 5A 31 34 34 52

Monitor 1, Cam 4, 4 Seconds

P64Z113V

50 36 34 5A 31 31 33 56

Monitor 1, Cam 1, 3 Seconds

P64Z123U

50 36 34 5A 31 32 33 55

Monitor 1, Cam 2, 3 Seconds

P64Z133T

50 36 34 5A 31 33 33 54

Monitor 1, Cam 3, 3 Seconds

P64Z143S

50 36 34 5A 31 34 33 53

Monitor 1, Cam 4, 3 Seconds

P64Z112W

50 36 34 5A 31 31 32 57

Monitor 1, Cam 1, 2 Seconds

P64Z122V

50 36 34 5A 31 32 32 56

Monitor 1, Cam 2, 2 Seconds

P64Z132U

50 36 34 5A 31 33 32 55

Monitor 1, Cam 3, 2 Seconds

P64Z142T

50 36 34 5A 31 34 32 54

Monitor 1, Cam 4, 2 Seconds

P64Z111X

50 36 34 5A 31 31 31 58

Monitor 1, Cam 1, 1 Second

P64Z121W

50 36 34 5A 31 32 31 57

Monitor 1, Cam 2, 1 Second

P64Z131V

50 36 34 5A 31 33 31 56

Monitor 1, Cam 3, 1 Second

P64Z141U

50 36 34 5A 31 34 31 55

Monitor 1, Cam 4, 1 Second

Time Adjust Commands...
The following Time Adjust commands alter the amount of time each camera
view appears on the screen. Making time adjustments via these RS-232 will
override any physical adjustments made using the “Time Adjust” control on
the P-6014.

You can use either the global commands, which will set the time adjustment
on all the cameras, or you can use commands for the specific camera inputs.
This allows you to set different viewing times for each of the camera inputs.
For example, if camera 1 is the most important camera, you might want to set
it to show for 10 seconds, while cameras 2, 3, and 4 are set for 1 second.
These time settings will remain in the P-6014’s memory. For example, if you
send a command to switch to a specific camera view and then another
command to return back to the cycle mode, time settings for the cycle mode
will be the same as they were before you switched to the specific camera
view. Note: Any movement of the Time Adjust control will cause the unit to
enter the cycle mode and will override the time adjustment settings made via
the serial controller.

11

ASCII Command

Hex Command

Function

Monitor 2 Time Adjust Commands

P64Z218P

50 36 34 5A 32 31 38 50

Monitor 2, Cam 1, 15 Seconds

P64Z228O

50 36 34 5A 32 32 38 4F

Monitor 2, Cam 2, 15 Seconds

P64Z238N

50 36 34 5A 32 33 38 4E

Monitor 2, Cam 3, 15 Seconds

P64Z248M

50 36 34 5A 32 34 38 4D

Monitor 2, Cam 4, 15 Seconds

P64Z217Q

50 36 34 5A 32 31 37 51

Monitor 2, Cam 1, 10 Seconds

P64Z227P

50 36 34 5A 32 32 37 50

Monitor 2, Cam 2, 10 Seconds

P64Z237O

50 36 34 5A 32 33 37 4F

Monitor 2, Cam 3, 10 Seconds

P64Z247N

50 36 34 5A 32 34 37 4E

Monitor 2, Cam 4, 10 Seconds

P64Z216R

50 36 34 5A 32 31 36 52

Monitor 2, Cam 1, 7.5 Seconds

P64Z226Q

50 36 34 5A 32 32 36 51

Monitor 2, Cam 2, 7.5 Seconds

P64Z236P

50 36 34 5A 32 33 36 50

Monitor 2, Cam 3, 7.5 Seconds

P64Z246O

50 36 34 5A 32 34 36 4F

Monitor 2, Cam 4, 7.5 Seconds

P64Z215S

50 36 34 5A 32 31 35 53

Monitor 2, Cam 1, 5 Seconds

P64Z225R

50 36 34 5A 32 32 35 52

Monitor 2, Cam 2, 5 Seconds

P64Z235Q

50 36 34 5A 32 33 35 51

Monitor 2, Cam 3, 5 Seconds

P64Z245P

50 36 34 5A 32 34 35 50

Monitor 2, Cam 4, 5 Seconds

P64Z214T

50 36 34 5A 32 31 34 54

Monitor 2, Cam 1, 4 Seconds

P64Z224S

50 36 34 5A 32 32 34 53

Monitor 2, Cam 2, 4 Seconds

P64Z234R

50 36 34 5A 32 33 34 52

Monitor 2, Cam 3, 4 Seconds

P64Z244Q

50 36 34 5A 32 34 34 51

Monitor 2, Cam 4, 4 Seconds

P64Z213U

50 36 34 5A 32 31 33 55

Monitor 2, Cam 1, 3 Seconds

P64Z223T

50 36 34 5A 32 32 33 54

Monitor 2, Cam 2, 3 Seconds

P64Z233S

50 36 34 5A 32 33 33 53

Monitor 2, Cam 3, 3 Seconds

P64Z243R

50 36 34 5A 32 34 33 52

Monitor 2, Cam 4, 3 Seconds

P64Z212V

50 36 34 5A 32 31 32 56

Monitor 2, Cam 1, 2 Seconds

P64Z222U

50 36 34 5A 32 32 32 55

Monitor 2, Cam 2, 2 Seconds

P64Z232T

50 36 34 5A 32 33 32 54

Monitor 2, Cam 3, 2 Seconds

P64Z242S

50 36 34 5A 32 34 32 53

Monitor 2, Cam 4, 2 Seconds

P64Z211W

50 36 34 5A 32 31 31 57

Monitor 2, Cam 1, 1 Second

P64Z221V

50 36 34 5A 32 32 31 56

Monitor 2, Cam 2, 1 Second

P64Z231U

50 36 34 5A 32 33 31 55

Monitor 2, Cam 3, 1 Second

P64Z241T

50 36 34 5A 32 34 31 54

Monitor 2, Cam 4, 1 Second

ASCII Command

Hex Command

Function

Global Time Adjust Commands

P64ZAT8[rs]

50 36 34 5A 41 54 38 1E

Global, All Cams, 15 Seconds

P64ZAT7[us]

50 36 34 5A 41 54 37 1F

Global, All Cams, 10 Seconds

P64ZAT6[sp]

50 36 34 5A 41 54 36 20

Global, All Cams, 7.5 Seconds

P64ZAT5!

50 36 34 5A 41 54 35 21

Global, All Cams, 5 Seconds

P64ZAT4”

50 36 34 5A 41 54 34 22

Global, All Cams, 4 Seconds

P64ZAT3#

50 36 34 5A 41 54 33 23

Global, All Cams, 3 Seconds

P64ZAT2$

50 36 34 5A 41 54 32 24

Global, All Cams, 2 Seconds

P64ZAT1%

50 36 34 5A 41 54 31 25

Global, All Cams, 1 Second