Adjusting the separation roller gap, See “adjusting the separation roller gap” on p. 21 – Canon FORMULA CR-80 User Manual

Page 21

Advertising
background image

21

Adjusting the Separation Roller Gap

If double feed should occur too often, adjust the Separation Roller gap
according to the following procedure.

IMPORTANT

• Make sure that the size, thickness, and weight of your document

meets the conditions of this scanner. See “Documents” on p. 6.

• Your unit has been carefully adjusted to meet most conditions.

However, the below adjustment may be needed depending on your
environment (humidity, temperature, etc.) and the documents you
are scanning (checks, etc.). Perform the adjustment only if
necessary.

1

Hook your finger around the open lever and open the
Maintenance Cover.

2

Pull out the document feed tray.

3

Load two checks or check-stock paper together.

4

Slide the two sheets through between the feeding roller
and the separation roller and stop at the position shown
below.

NOTE

If you were unable to slide both sheets through the gap between the
rollers, turn the paper thickness adjustment dial counter-clockwise
(left) until both sheets two pieces easily slide through the gap.

Separation
Roller

Feeding
Roller

Paper Thickness
Adjustment Dial

Two Sheets

Advertising
This manual is related to the following products: