Wiring, Watertight connector nut, Insert the operator cable – Chamberlain LA412 User Manual

Page 21

Advertising
background image

FUSE
OPEN

Mo

vin

g G

ate

Can

Caus

e

Injur

y or

Death

KEEP

CLEAR!

Gate

ma

y m

ove

at

any

tim

e w

itho

ut p

rior

warn

ing

.

Do n

ot le

t ch

ildre

n o

pera

te th

e g

ate

or

pla

y in

the

ga

te a

rea

.

Thi

s en

tran

ce i

s fo

r ve

hic

les

onl

y

Ped

est

rian

s m

ust

use

sep

ara

te e

ntra

nce

FUSE
OPEN

C4

Control Box

18

18

R93

R93

D42

K2K2

Z22Z22

P1P1

F2F2

MO

V1

D1D1

Q12

D129

Z4

U3U3

D2

D2

D44

C11C11

C13

D16D16

F9F9

K1K1

Q22

F3

F3

K3

K4

R196

F1

F1

Z12

Z12

GATE 2

GATE 2

GR

GR

WH

WH

YL

YL

BL

BL

RD

RD

BR

BR

F7

24V

24V

GATE 2

SET

SET

OPEN

OPEN
LIMIT

LIMIT

SET

SET

CLOSE

CLOSE

LIMIT

LIMIT

LEARN
LIMITS

GATE 1

C69C69

J2Ø

D8

D4

R9R9

R329R32

9

R27R27

MO

V2

MO

V2

R4R4

C2C2

Z1

K5K5

F12

F12

Q9Q9

R9Ø

F8

F8

Q6

Q1

C75

C75

C66

C66

C65

C65

C68C68

C33C33

F11

R42

R42Ø
R423

R423

J24 J23 3Ø

A 32V

3 3

Ø

A 32VA

32V

J21J21

3030

3030

C64C64

R22

R22

U2

U2

K6

K6

JU1JU1

JU2

DB1

D36

D36

To reduce the risk of SEVERE INJURY or DEATH:
• BEFORE installing power wiring or control stations be sure to

follow ALL specifi cations and warnings described below.

• ANY maintenance to the operator or in the area near the

operator MUST not be performed until the batteries are
disconnected. Upon completion of maintenance the area
MUST be cleared and secured, at that time the unit may be
returned to service.

• ALL electrical connections MUST be made by a qualifi ed

individual.

• DO NOT install ANY wiring or attempt to run the operator

without consulting the wiring diagram. We recommend that
you install an optional reversing edge BEFORE proceeding
with the control station installation.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

WARNING

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Connect the Gate Operator (Gate 1) to the Control Box

1

WATERTIGHT CONNECTOR NUT
Insert the operator cable through the watertight
connector nut.

Watertight Connector Nut

Operator
Cable

2

INSERT THE OPERATOR CABLE
Insert the watertight connector into the bottom of the control box
and tighten with nut. Insert the operator cable through the watertight
connector mounted in the bottom of the control box.

Nut

Watertight

Connector

Operator

Cable

Watertight

Connector

Watertight

Connector Nut

Operator Cable