• The gate with the longer travel span (opening) must be set as the primary gate (GATE 1).

• If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other

gate; gate 2 may need to be closed fi rst if there is overlap or a gate lock is being used.

• The programming can be exited at any time by pressing the RESET button. Programming times-out automatically after 60 seconds of

inactivity.

Programming 34

Press the GATE 1 right button to open the left operator.

Press the GATE 1 left button to open the right operator.

SET

CLOSE

DIAGNOSTIC

GATE 1

FORCE

GATE 2

SET

CLOSE

LIMIT

LE
LIMIT

SET

CLOSE

DIAGNOSTIC

GATE 1

FORCE

GATE 2

SET

CLOSE

LIMIT

LE
LIMIT

When the SET CLOSE LIMITS LED blinks, press the
GATE 2 left button to close the right operator.

When the SET CLOSE LIMITS LED blinks, press the
GATE 2 right button to close the left operator.

FORCE

GATE 2

SET

CLOSE

LIMIT

LE
LIMIT

SET

CLOSE

DIAGNOSTIC

GATE 1

SET

CLOSE

DIAGNOSTIC

GATE 1

FORCE

GATE 2

SET

CLOSE

LIMIT

LE
LIMIT

The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is
now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see
Troubleshooting section.)
Test the limits by pressing the SBC to open and close the gate.

DUAL GATE (LEFT-SIDE PRIMARY OPERATOR)

DUAL GATE (RIGHT-SIDE PRIMARY OPERATOR)

Press the GATE 2 right button to move the right operator

into the OPEN position.

Press the LEARN LIMITS button. Control board will beep.

Press the GATE 2 left button to move the left operator into
the OPEN position.

Press the LEARN LIMITS button. Control board will beep.

Press the GATE 1 left button to close the left operator.

Press the LEARN LIMITS button.

Press the GATE 1 right button to close the right operator.

Press the LEARN LIMITS button.

SET

OPEN

LIMIT

N
T

PROGRAM OPEN

PROGRAM OPEN

PROGRAM CLOSE

PROGRAM CLOSE

With the gate in the CLOSED position, press the LEARN
LIMITS
button (SET OPEN LIMIT LED will blink).

With the gate in the CLOSED position, press the LEARN
LIMITS
button (SET OPEN LIMIT LED will blink).