Know about your water softener – Kenmore ULTRASOFT 175 625.388170 User Manual

Page 19

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION 4

A. DIMENSIONS / SPECIFICATIONS

Pressure Drop (PSI) vs. Flow Rate (GPM)

KNOW ABOUT YOUR WATER SOFTENER

Intermittent flow rate does not represent the maximum service flow rate used for determining the softeners
rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate may affect
capacity and efficiency performance.

SPECIFICATIONS

UitraSoft175

UitraSoft 180

Type of ion exchange material (resin)

high capacity

high capacity

Amount of resin (cu ft)

.78

.84

Rated Softening Capacity (Grains @ Pounds Salt Dose)

11,800 @ 2.3

25,300 @ 7.4

30,200 @ 12.5

12,800 @2.5

27,300 @ 8.0

32,500 @ 13.4

Efficiency Rating (Grains/Pound of Salt @ Minimum Sait Dose

5120 @2.3

5100 @2.5

Rated Service Flow Rate (gpm)

7.5

7.5

Pressure Drop at Rated Service Flow Rate (psi)

14

15

Max. Drain Flow Rate (gpm) to Drain During Regeneration Cycle

2.0

2.0

These systems conform to NSF/ANSI 44 for the specific performance claims as verified and substantiated
by test data.

The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency rated
according to NSF/ANSI Standard 44.

________________________________________________ _____________________________________________________

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Advertising
This manual is related to the following products: