fn=12 Function 12 Sending the Set Communication Conditions

GS ( E pL pH fn a

[Code]

<

1D>H<28>H<45>H<pL><pH><fn><a>

[Range] (pL+pH×256)=2 (pL=2、pH=0)

fn=12
1≦a≦4 (Does not send in other than specified range)

[Outline]

[The specification which is common to the model]

Sends communication conditions of serial interface specified by “a”.

Hex.

No. of Data

37H 1

Header

33H 1

ID

31H(“1”)~34H(“4”)

1

Kind of communication conditions (a)

1FH 1

Separation number

30H~39H 1~6

Set value

00H 1

NULL

Set value

• a = 1: At specification of baud rate

Baud

Rate d1 d2 d3 d4 d5 d6

1200

49(“1”) 50(“2”) 48(“0”) 48(“0”) ----

----

2400

50(“2”) 52(“4”) 48(“0”) 48(“0”) ----

----

4800

52(“4”) 56(“8”) 48(“0”) 48(“0”) ----

----

9600

57(“9”) 54(“6”) 48(“0”) 48(“0”) ----

----

19200

(Default) 49(“1”) 57(“9”) 50(“2”) 48(“0”) 48(“0”) ----

38400

51(“3”) 56(“8”) 52(“4”) 48(“0”) 48(“0”) ----

57600

53(“5”) 55(“7”) 54(“6”) 48(“0”) 48(“0”) ----

115200

49(“1”) 49(“1”) 53(“5”) 50(“2”) 48(“0”) 48(“0”)

●・・・

support by

CT-S2000

CT-S4000

• a = 2: At specification of parity

d

Parity Setting

48

No parity

49 Odd

parity

50 Even

parity

• a = 3: At specification of flow control

d

Flow Control

48 DTR/DSR
49 XON/XOFF

• a = 4: At specification of data length

d1 Setting

Data

Length

48

7-bit length

49 8-bit

length